Energy Sizing Data updated 2026-11-09

How big a backup does an outage actually need

Almost everyone searches for this with one number in mind: the size of the machine. The size is the last thing you work out. The first is how many days you intend to stay in the house, because a battery sized for one evening is about a third of the one sized for three days.

How to read this page

Enter the daily energy of the kit you want to keep running, the outage length you are planning for, and what you already have. The calculator splits the answer into the part the panels supply each day and the part the battery has to carry, then returns the bank size that closes the gap. If the panels out-produce the kit, the outage length stops mattering — that is the one case where more days cost nothing.

Some links on this page are Amazon affiliate links. As an Amazon Associate we earn from qualifying purchases. The price you pay is the same, and no brand can pay for a position here.

The question behind the search

The phrase "what size generator for a power outage" is asked by two different households. One wants to know whether the fridge survives the evening. The other wants to know whether the house is habitable on day four. Those are not the same purchase, and the difference is roughly a factor of three.

There is also a units problem. Machines are sold by output in watts, while an outage consumes energy in watt hours over days. A 2,000 W machine and a 2,000 Wh battery carry the same two numbers and answer different questions: one is a rate, the other is a quantity. This page works in energy and converts to a bank size at the end.

So the calculation has three inputs and one output. The inputs are how much the kit uses per day, how many days the outage lasts, and what the panels contribute. The output is the battery size that covers what the panels do not.

The order matters. Households that start with the machine usually start with a wattage they saw in a review, then discover the kit it can actually run is smaller than expected. Households that start with the kit usually discover the machine they need is cheaper than they feared, because the loads that matter are few.

There is also a useful sanity check at the end. If the answer is several times the capacity of the largest single unit sold, the purchase has quietly become a fixed system, and that is a different budget and a different set of rules. Knowing when the arithmetic crosses that line saves a lot of shopping.

What the kit uses per day

Start with the loads you would genuinely keep running, not with the whole house. Three kits cover most households, and the wattage figures are category typical values rather than measurements of your appliances.

Typical daily energy for three outage kits
KitWhat runsDaily energy
MinimalRouter, four LED bulbs, phonesAbout 300 Wh
Refrigerator and basicsThe above plus an 18 cu ft fridge at 50 % dutyAbout 1,500 Wh
Comfort in a cold snapThe above plus a 400 W space heater at nightAbout 2,900 Wh

The third row is why heating deserves its own warning. A space heater is a resistance load with no efficiency trick, so a few hours of it exceeds a whole day of everything else. If heat is in the plan, the purchase stops being portable at all.

The load calculator produces this figure from your own list of appliances rather than a kit template, and the appliance wattage library has the per-device numbers behind it.

One caution about the refrigerator row. A fridge is listed with a running wattage and a starting wattage, and the starting figure is several times larger. The daily energy uses the running figure multiplied by duty cycle; the machine specification that matters is the starting figure, because a unit that cannot surge cannot start the compressor at all regardless of capacity.

Duty cycle is the number people guess wrong. A refrigerator compressor runs roughly half the time in a warm kitchen and much less in a cold one, which is why two households with identical fridges report daily figures that differ by a third.

How the length of the outage changes the answer

This is the part that surprises people. Doubling the outage does not double the cost, because the panels keep working on every one of those days. It doubles the deficit, which is a smaller number.

A 2,400 Wh daily kit with 400 W of panels at 4.5 sun hours
OutageEnergy neededPanels supplyDeficitBank needed
1 day2,400 Wh1,440 Wh960 Wh1,129 Wh
3 days7,200 Wh4,320 Wh2,880 Wh3,388 Wh
7 days16,800 Wh10,080 Wh6,720 Wh7,906 Wh

Read the last two columns together. Going from one day to three multiplies the bank by three, which is expected. Going from three days to seven multiplies it by about 2.3, which is the panels paying for part of the extra time. The larger the array relative to the kit, the flatter that growth becomes.

This is also why a household with a small array should size for the outage it will actually stay for. A bank that covers seven days is usually money spent on a scenario where the family has already left.

The daily balance, and the day it breaks

Write the daily balance as a subtraction: production during the day, use over twenty-four hours. If the result is negative, the battery drains a little every day and the outage length decides whether it survives. If the result is positive, the battery is only being used to move energy from noon to midnight.

For a 2,400 Wh kit, a 400 W array at 4.5 sun hours makes about 1,440 Wh a day, so the balance is minus 960 Wh. A 2,048 Wh battery holds about 1,741 Wh usable at 85 % depth of discharge, which covers 1.81 days. On day two of an outage, that configuration is already relying on sunshine it may not get.

The break point is worth calculating for your own numbers, because it is where the whole argument about array size lives. Solve for the array that makes production equal use, then compare it with what your roof or balcony can actually hold.

The battery sizing calculator runs the same balance from the array side, and the storage sizing calculator starts from the load instead.

For the running example that break point is 2,400 Wh divided by 4.5 sun hours and 80 % system efficiency, which is an array of about 667 W. Below that the battery drains every day of the outage; above it the battery only moves energy from noon to evening and the outage length stops being a constraint on capacity.

That single calculation explains most of the disagreement in this category. A household with a balcony array is usually below the break point and genuinely needs a large bank. A household with a full roof array is above it and needs a much smaller one than the load figure suggests.

Turning the deficit into a bank size

The deficit is the energy the battery has to deliver across the outage. Dividing it by the depth of discharge gives the nameplate figure, which is the number on the box.

Deficit to nameplate, at three depths of discharge
DeficitAt 85 %At 80 %At 70 %
960 Wh1,129 Wh1,200 Wh1,371 Wh
2,880 Wh3,388 Wh3,600 Wh4,114 Wh
6,720 Wh7,906 Wh8,400 Wh9,600 Wh

The spreadsheet version of this is one line, and it is worth doing by hand once so the box label stops being a mystery. A maker who permits 85 % is selling you more usable energy from the same cells than one who permits 70 %, which is a real difference in cost per usable watt hour even when the nameplate is identical.

That is the reason to look for a usable figure rather than a nameplate figure, and the reason the chemistry comparison puts depth of discharge above cell chemistry in importance.

There is a practical ceiling to keep in mind. Two units of the same brand can usually be linked, and the combined capacity is the sum, but the output often is not. A pair sized for a three-day outage may still be unable to start a fridge if each unit is small, which is why the surge figure has to be checked on the unit that actually feeds the compressor.

Linking also changes the wiring question. Two units on a bench are still two appliance loads rather than a house supply, so anything beyond plugging devices into them needs the same electrical work as a single larger unit.

What the calculation leaves out

Four omissions matter enough to state before the result is trusted.

Heating and cooling. A heat pump or a central air conditioner is a 240 V load and outside the portable category entirely. A resistance heater fits the arithmetic and ruins it, because it dominates the daily total.

Overcast days. Sun hours are an annual planning average. A week of storms can halve production for days at a time, so a system that is exactly balanced on paper fails exactly when the outage happens.

Standby losses. Inverters draw a few watts doing nothing, which matters over seventy-two hours in a way it does not over one evening.

Transfer losses. Any changeover equipment between the battery and the house wiring costs a little energy and, in most homes, requires an electrician.

The honest way to use the result is to add margin and then check it against the worst day rather than the average one.

A useful habit is to run the calculator twice: once with the sun hours you would see in June, and once with half of them. The gap between the two results is the margin the plan actually needs, and it is usually larger than people expect in the northern half of the country.

Standby losses deserve a number rather than a mention. An inverter idling at five watts spends 120 Wh a day doing nothing, which is a tenth of a minimal kit and worth knowing before a three-day outage is planned around a tight bank.

Three kits that behave differently

The same outage asks for very different hardware depending on what is on the list.

The refrigerator kit. A fridge is a compressor, so it needs a surge rating several times its running watts. Capacity alone will not start it. This is the kit where the surge figure on the box decides the purchase.

The medical kit. A CPAP or a concentrator runs all night, which shifts the demand to the dark hours. Panels contribute nothing at the time of use, so the battery carries the whole load and the array only refills it. Size the battery for the night and the array for the refill.

The work-from-home kit. Modems, a laptop and a monitor are small and steady, and they are the easiest kit to cover. A 288 Wh station runs this for most of a working day, which is why the smallest units exist at all.

Those three are different purchases, and the calculator above is what separates them before money is spent. Two other situations point away from a portable battery entirely, and it is worth saying so on a page that sizes them.

Two situations point away from a portable battery and it is worth saying so on a page that sizes them.

A multi-day outage with 240 V loads in scope. A well pump, a dryer or a central air conditioner cannot run from a 120 V box, so no amount of capacity helps. That is a generator or a fixed system with a transfer switch, and this calculator is the wrong tool.

A household that will evacuate. If the plan is to leave for anything longer than a night, a large bank is insurance against a scenario that will not happen. A small station for the first evening plus a decision rule to leave is cheaper and just as effective.

Where fuel generators are the realistic alternative, the comparison of a battery station against a gas generator covers the trade honestly, including the outdoor siting rule that decides it for many households.

Banks in the sizes this calculator asks for

These are recorded units across the range, ordered by capacity. None of them carries a printed price here, because a printed price is wrong within weeks; the retailer's page is the only current source.

Working-day kit

Anker SOLIX C300

288 Wh at 300 W. Covers a work-from-home kit for a day and nothing with a compressor.

288 Wh · 300 W

Check current price

One evening

BLUETTI AC70

768 Wh at 1,000 W. The first tier where a fridge start is comfortable rather than marginal.

768 Wh · 1,000 W

Check current price

One night

EcoFlow DELTA 3

1,024 Wh at 1,800 W. About 2.9 hours of a 300 W kit at the usual depth of discharge.

1,024 Wh · 1,800 W

Check current price

One night, with surge

Anker SOLIX C1000 Gen 2

1,024 Wh with 2,000 W continuous and a published 3,000 W surge, which is what a compressor needs.

1,024 Wh · 2,000 W · 3,000 W surge

Check current price

Two days at low load

Jackery Explorer 2000 v2

2,042 Wh at 2,200 W. Covers the minimal kit across several days and the fridge kit for one.

2,042 Wh · 2,200 W

Check current price

Two days at low load

BLUETTI AC200L

2,048 Wh at 2,400 W. The same capacity as the row above with more continuous output for a kettle.

2,048 Wh · 2,400 W

Check current price

A day with margin

Anker SOLIX F2600

2,560 Wh at 2,400 W. Covers a fridge kit for a day with headroom for lights.

2,560 Wh · 2,400 W

Check current price

A day with panels

Jackery 2000 v2 with 400 W of panels

The bundle that makes the balance arguable across days rather than hours, in summer.

2,042 Wh · 2,200 W · 400 W panels

Check current price

Largest single box

EcoFlow DELTA Pro 3

4,096 Wh at 4,000 W. The top of the portable category, and the point where a fixed system competes.

4,096 Wh · 4,000 W

Check current price

Array for the refill

Renogy 400 W foldable

Two 200 W panels in one case. Check the station's input cap before assuming both are useful.

400 W · 2 × 200 W

Check current price

For the ranking behind these picks, the portable power station comparison sorts the same units by capacity and output, and the home backup comparison covers sustained multi-day coverage.

Five mistakes with this arithmetic

Sizing by watts instead of watt hours. A 2,000 W output says nothing about how many days it lasts, and the days are what an outage costs.

Using the whole house as the kit. The daily total then becomes 30,000 Wh and the answer is a fixed system, which may be right, but it is not the purchase being searched for.

Forgetting the surge. A battery that holds enough energy but cannot surge will not start a fridge, and the compressor is the whole point of the purchase.

Planning around the average day. An outage happens in bad weather, when panels produce least. Add margin for the worst day, not the average one.

Buying for a seven-day event you would evacuate from. The most common overspend in this category is a bank sized for a scenario the household will not stay for.

If a figure here disagrees with a calculator on this site, the calculator is the source of truth and the changelog records each correction.

The common thread across all five is planning in the wrong unit. Outages are measured in days, batteries are sold in watt hours, and machines are advertised in watts. Converting everything to watt hours before comparing anything prevents most of these mistakes at once.

Questions

How big a generator or battery do I need for a power outage?

It depends on the length of the outage, not on the house. Multiply the daily energy of the kit you want to keep running by the number of days, subtract what panels supply each day, then divide the remainder by the depth of discharge the battery allows. A three-day outage of a 2,400 Wh daily kit with 400 W of panels leaves about 2,880 Wh of deficit, which needs roughly 3,388 Wh of nameplate battery.

Why does the answer change so much between one day and three days?

Because the battery has to cover a deficit that grows with every day, while the panels keep replacing only one day at a time. A bank that covers a single evening is roughly one third of the bank that covers three days at the same load.

Do panels change the answer much?

Only if they are large enough to matter against the load. A 400 W array at 4.5 sun hours makes about 1,440 Wh a day, which is a real contribution to a 2,400 Wh kit and negligible against a 12,000 Wh one. The ratio of daily production to daily use is the number that decides whether the panels are part of the answer.

Should I size for the average outage or the worst one?

Size for the outage you would actually stay in the house for. Most households evacuate for the extreme event, so a bank sized for two or three days plus an alternative plan is more useful than a bank sized for a week that is never used.

What does the calculation leave out?

It leaves out heating and cooling, which usually dominate and are hard to run from 120 V anyway, the losses of a transfer switch, and the reduced panel output of overcast winter days. Treat the result as a planning figure and add margin rather than treating it as a guarantee.

This page is research and arithmetic, not electrical advice. Anything that connects a battery or a generator to house wiring needs a licensed electrician and, in most places, a permit and an inspection.

Daily energy figures are category typical values, not measurements of your appliances, and sun hours are annual planning averages rather than a forecast. Add margin before buying.